Cookie Img
Send Inquiry Send SMS    Call Me Free
Home » Products » Patient Monitor » Multipara Monitors CMS 8000

Multipara Monitors CMS 8000

Multipara Monitors CMS 8000
Multipara Monitors CMS 8000
Product Code : 25
Brand Name : Meditech Electronics
Product Description

Multipara Monitors CMS 8000

We offer CMS 8000 model are known for their wide functionalities. These are used to report respiration, SPO2, ECG, Temperature, RESP, monitor, essential measurement parameters such as SpO2, TEMP, ECG, PR/HR, RESP and NIBP. These monitors are designed by latest digital technology which gives excellent accuracy. 

Technical Specifications :

·        Display:High 12.1″color TFT display 

·        Safety: IEC60601 (GB9706

·        Dimensions     340mm(W)x270m(H)215mm(D)

·        Power Supply: 90-280V AC 50Hz/60Hz

·        Alarms Indication: Visual and audible alarm

·        1000 groups of alarms events review

·        Application: Adult, pediatric and neonate
NIBP:
 

·        Method: Oscillometry

·        Modes: Manual/Auto/Continuous

·        Auto measure time: Adjustable

·        Measurement rang: 10-270mmHg 

·        ECG:

·        Lead mode: 3-lead or 5-lead

·        Lead selection: I; II; III; AvR; AvL; AvF; V

·        Heart rate range: Adult: 15-300bpm; Pediatric/Neonatal: 15-300bpm

·        ECG waveform: 2 channels

·        Accuracy: ± 1 bpm or ± 1% *S-T segment detection Measurement rang: -0.2mv~2.0mv * Alarm: Yes, audible and visual alarm, alarm events review *High resolution 12.1"color TFT display

·        Lightweight, compact and portable *ECG, APO2, NIBP, RESP, 2-TEMP, PR *Optional: 2-IBP, ETCO2, And thermal printer

·        Bulit-in rechargeable lithium battery

·        ECG waveforms of 7-leads display on the same screen *72-hours graphic and tabular trends of all parameters * 72 alarm events of all parameters recall *32 seconds full-disclosure waveform review *500 NIBP measurement date can be storage and recall

·        Date and waveforms color be adjustable

·        Arrhythmia analysis and S-T segment analysis

·        Suitable for adult, pediatric and neonatal patient 


SPO2(Pulse Oximetry) :

·        Measurement range: 0-100%

·        Accuracy: 70-100%, ± 2% 0-69%, unspecified Pulse rate

·        Range: 20-254bpm

·        Accuracy: ± 3bpm 


Respiration :

·        Method: RA-LL impedance

·        Range: Adult: 0-120rpm; Pediatric/neonatal: 0-150rpm

·        Apnca alarm Yes 

Other Information

·        Pay Mode Terms: T/T (Bank Transfer)



Mfg Unit : J-81, Sector-4, DSIIDC, Bawana Industrial Area, Land Mark Near Fire Service, Delhi - 110039, India
Phone :91-11-27762484
Mr. S. B. Nain (C.E.O.)
Mobile :+919868165949, +919210333574, +919811225949, +919811165949
Corp Office : 410 , SG Shopping Complex , D.C.Chowk, Sec -9 , Rohini ,Delhi -110085
   Call Me Free Offline Send SMS Send Inquiry


Buyers Helpdesk

Let tradeindia.com find Quality Suppliers for you!

I agree to abide by all the Terms and Conditions of tradeindia.com
MEDITECH ELECTRONICS All Rights Reserved.